This V2G DC charger uses high-efficiency 20kW or 30kW air-cooled constant-power V2G charging modules and supports output voltages up to 800V. Bidirectional charging and discharging control allows energy to flow between the electric vehicle and the grid. The charger supports wall-side installation and is suitable for public charging stations, highway service areas, and other V2G charging applications.
- Protection Rating: IP55
- Operating Temperature: -30°C to +70°C (power derating above 55°C)
- Bidirectional Charge & Discharge Control: Supported
Technical Specifications
| Mechanical | Cooling System | Forced air cooling | Forced air cooling | Forced air cooling | Forced air cooling |
| Dimensions (W × D × H) | 850 × 500 × 1800 mm | 850 × 500 × 1800 mm | 850 × 500 × 1800 mm | 850 × 500 × 1800 mm | |
| AC Input | Rated Input Voltage | 380 Vac ± 20% | 380 Vac ± 20% | 380 Vac ± 20% | 380 Vac ± 20% |
| Grid Frequency | 45 ~ 65 Hz | 45 ~ 65 Hz | 45 ~ 65 Hz | 45 ~ 65 Hz | |
| Power Factor (PF) | ≥ 0.99 | ≥ 0.99 | ≥ 0.99 | ≥ 0.99 | |
| System Efficiency | ≥ 93% (At half load and above) | ≥ 93% (At half load and above) | ≥ 93% (At half load and above) | ≥ 93% (At half load and above) | |
| DC Output | Output Channels | Single connector | Single connector | Single connector | Single connector |
| Output Voltage | DC 150 ~ 750 V | DC 150 ~ 750 V | DC 150 ~ 750 V | DC 150 ~ 750 V | |
| Max. Current / Single Connector | 67 A | 100 A | 133 A | 200 A | |
| Max. Current / Total System | 67 A | 100 A | 133 A | 200 A | |
| Compliance | BMS Communication | Compatible with old and new standards, meeting the charging needs of old and new vehicle models | |||
| Protection | Operating Temperature | -30°C ~ +70°C (Derating above 55°C) | -30°C ~ +70°C (Derating above 55°C) | -30°C ~ +70°C (Derating above 55°C) | -30°C ~ +70°C (Derating above 55°C) |
| Protection Rating | IP55 | IP55 | IP55 | IP55 | |
| Dustproof Class | G3-level dust filter | G3-level dust filter | G3-level dust filter | G3-level dust filter | |
| Protection Functions | Input over/under voltage protection, Output overvoltage protection, Output overcurrent protection, Short circuit protection, Battery reverse connection protection, Insulation monitoring protection, Door enclosure protection, BMS data anomaly protection, Emergency stop protection, Electromagnetic lock anomaly protection, Abnormal un-plugging protection, Lightning/Surge protection, Anti-tilt alarm protection (optional), Flooding/Water-immersion alarm protection (optional), etc. | ||||